2 WIRES ISOLATED PROGRAMMABLE TRANSMITTER: TIT 6568

DIN form B sensor head mounting (DIN bar with accessory)

MAIN FEATURES:

  • - Input for thermocouples and mV.
  • - Linearized temperature measurement signals from thermocouples.
  • - Automatic cold junction compensation (CJC) with temperature sensor.
  • - Linear mV signal conversion to analog current 4 ... 20 mA.
  • - High accuracy.
  • - Galvanic isolation 1,5 kVac
  • - Continuous check of critical parameters stored.
  • - Programmable output value for failure.
  • - Fast programming for all temperature ranges.

    TC Min temp. Max temp. Min span Standard
    B   +400°C +1820°C 200°C IEC584
    E   -100°C +1000°C 50°C IEC584
    J   -100°C +1200°C 50°C IEC584
    K   -180°C +1372°C 50°C IEC584
    L   -100°C + 900°C 50°C DIN 43710
    N   -180°C +1300°C 100°C IEC584
    R   -50°C +1760°C 200°C IEC584
    S   -50°C +1760°C 200°C IEC584
    T   -200°C + 400°C 50°C IEC584
    U   -200°C + 600°C 75°C DIN 43710
    W3   0°C +2300°C 200°C ASTM E988-90
    W5   0°C +2300°C 200°C ASTM E988-90
    LR   -200°C + 800°C 50°C GOST 3044-84
• Voltage input: Measurement range
• Input resistance
• Supply voltage, DC
• Current output signal range
• Load resistance
• Max. wire size
• Operating Temperature - Humidity
• Dimensions
• Protection degree (encl. / terminal)
• Weight
-12...150 mV
10 M
7,2...28 V
4...20 mA
< (Vsupply - 7.2) / 0.023 [ohm]
1 x 1.5 mm2 stranded wire
-40...+85 °C < 95% RH (n.c.)
Ø 44 x 20.2 mm
IP68 / IP00
50 g

Download: Data Sheet - User Guide - Application examples

    